05/05/2004 FRAMING Approved IVRS - Inspection :*
05/04/2004 FRAMING Partial Approval IVRS - Inspection :*/ 1) TEST ON DWV 2) SHORE UP ON TRUSSES 3 POINT BEARING ON GARAGE HDR REMOVE 3) OK GAS PRESSURE TEST
05/03/2004 FRAMING Not ready for Inspection IVRS - Inspection :*/ 1) NO GAS PRESSURE 2) DWV NO WATER TEST 3) DBL 2 X 10 AT GARAGE FURNACE ROOM 4) LOOSE BOTTOM PLATE MASTER BATH 5) BLOCK MECH 6) RAT RUN AT RT6 TRUSSES