Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 05/05/2004 |
FRAMING |
|
Approved |
IVRS - Inspection :* |
| 05/04/2004 |
FRAMING |
|
Partial Approval |
IVRS - Inspection :*/ 1) TEST ON DWV 2) SHORE UP ON TRUSSES 3 POINT BEARING ON GARAGE HDR REMOVE 3) OK GAS PRESSURE TEST |
| 05/03/2004 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection :*/ 1) NO GAS PRESSURE 2) DWV NO WATER TEST 3) DBL 2 X 10 AT GARAGE FURNACE ROOM 4) LOOSE BOTTOM PLATE MASTER BATH 5) BLOCK MECH 6) RAT RUN AT RT6 TRUSSES |