Permit: T04CM01208

Parcel: 136326290

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
12/21/2004 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*
12/03/2004 ELECTRIC - INTERMEDIATE Not ready for Inspection 1) STUCCO LATH NOT COMPLETED
2) MOVE PEX H20 LINE 12' AWAY FROM CAN LIGHT AT SHOWER BANG PLATE CU. AT DIVERTER VALVE, STUD NOTCHED TOO DEEP
3) FIRE STOP AT FIREPLACE FLUE NOT SEALED
4) ELECTRIC, RECEPTS NOT ALLOWED UNDER KITCHEN COUNTER OVERHANG, YOU NEED ALTERNATE METHOD TO COMPLY WITH 4'-0" SPACING
5) BANG PLATE 3" ABS NORTH TOILET
6) TRAP ARM AT WEST BATH, TRAP AND ARM TO BE SAME SIZE, SHOULD BE 1 1/2" YOU OVER MAXIMUM DISTANCE EVEN FOR 2" YOU NEED TO REVENT, WITH PROPER PITCH
7) GAS PRESSURE TEST OK
11/17/2004 ELECTRIC - INTERMEDIATE Partial Approval
11/12/2004 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*