Permit: T04CM01208

Parcel: 136326290

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
01/03/2005 FRAMING Approved IVRS - Inspection :*
12/21/2004 FRAMING Not ready for Inspection IVRS - Inspection :*
1) IVR SYSTEM DOWN, COULDN'T RETRIEVE MESS
2) PLAN CALLS FOR 1 1/2" H20 YARD LINES YOU HAVE 1 1/4"
3) SISTER AT 2 X 4 AT SHOWER DIVERTER, STUD IS NOTCHED TO DEEP 3RD TIME, OK TO INSULATE BUT RECALL FRAMING
4) SMALL PATCH AT FRON OF HOUSE IN STUCCO LATH, THE LAP IN THE WIRE NOG BIG ENOUGH MINIMUM 1 1/2" LAP ALL AROUND 2ND TIME-OK TO STUCCO
12/16/2004 FRAMING Not ready for Inspection IVRS - Inspection :*
1) SHOWER DIVERTER FROM LAST INSPECTION STUD NOTCH TO DEEP, NEED BANG PLATE AT CU #4 ABOVE KITCHEN RECEPTACLES
3) #5 BANG PLATE NORTH TOILET
4) #6 ABOVE TRAP ARM
5) LATH PATCH AT FRONT WALL MINIMUM 1 1/2" LAP ON WIRE
6) UNABLE TO LOCATE PLAN
12/03/2004 FRAMING Not ready for Inspection IVRS - Inspection :*
11/15/2004 FRAMING Not ready for Inspection IVRS - Inspection :*
11/12/2004 FRAMING Partial Approval IVRS - Inspection :*/ 1) PEX TOUCHING RECESSED CAN IN HALLWAY
2) COMPLETE CHIMNEY FIREBLOCKING
3) COMPLETE RECEPTACLE WIRING MASTER BATH
4) ADD RECEPTACLE FROM CLOSET WALL
5) SEE PLAN
6) WIRE FIREPLACE
7) ROOFING ? TOUCHING B-VENT IN FURNACE ROOM
8) FINAL FRAME REQUIRES THAT ALL INTERMEDIATES ARE COMPLETE