Permit: T04CM01195

Parcel: 120084070


Addresses:

147 W TENNESSEE ST

Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Date Description Inspector Results Comments
05/18/2004 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection :*
05/12/2004 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) PER APPROVED DRAWING FOOTING SHALL BE AS INDICATED ON DRAWING 24" X 12" 2) WRAP ALL PLUMBING IN CONTACT WITH CONCRETE 3) WATER TEST ON SOIL PLUMBING SHALL BE 10'-0" HIGH 4) SEWER SLOPE (VERIFY 1/4" FOOT SLOPE) 5) LEAK AT SIDE OUTLET FIXTURE 6) PVC AND AB'S SHALL NOT BE MIXED 7) SANITARY "T" NOT ALLOWED FOR 2 WAY CLEANOUT
05/05/2004 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) SANITARY 'T' FITTING CANNOT BE INSTALLED IN THE FLAT AS DRAIN FITTINGS. USE COMBINATION T/Y FITTING OR Y FITTINGS 2) SEWER LINE MUST BE 12" BELOW GRADE OR USE DUCTIL IRON PIPE 3) YOU NEED TO INSTALL A UFER GROUND NOW 4) WRAP ALL PLUMBING THAT WILL BE IN CONTACT WITH APPROVED CLOSET WRAP. NOT PER PACK GAS WRAP 5) TOILET NOT PROPERLY VENTED. PLAN INCORRECT