Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
Permit Number - T04CM01155
Inspection Description - ELECTRIC - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/28/2004 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* | |
06/25/2004 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :*/ RANGE CABLE NOT APPROVED - NEED #6 PER PLAN. OK TO COVER X THIS AREA. S.T.O.I. - NEED TO USE PROPER CRIMPER FOR CRIMP SLEEVE EG: T&B CRIMPER WT 3 (?). IN FUTURE UTILIZE ROMEX CONNECTOR IN BOX - DO NOT REMOVE. | |
06/18/2004 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245*/ SER AZ NOT SUITABLE FOR WET LOCATION. 8/3 ROMEX NOT SUITABLE FOR 50 AMPS. UPPER BED - SW - MORE THAN 6 FT ABOVE FROM BEGINNING OF ROOM. KITCHEN HAS PULLED WIRES OUT OF BOX. |