Permit: T04CM01140

Parcel: 110102520

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
07/17/2004 FRAMING Approved IVRS - Inspection :*
07/13/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) TIGHTEN HOLDOWNS AT GARAGE FRONT 2) HOLES DRILLED TOO CLOSE TO BOTTOM CORD OF GARAGE TJI'S FOR WATER LINES 3) PROTECT PEX AT CUT STEEL ABOVE GARAGE PEDESTRIAN DOOR AND AT MASTER TUB 4) MOVE PEX 12" FROM MASTER BATH CAN LIGHT AND BREEZEWAY CAN LIGHTS 5) FINISH HOME RUN INSTALL AT PANEL 6) PROTECT PEX AT CUT STEEL NORTH OF BREEZEWAY CANF LIGHTS AN SOFFIT CAN LIGHTS 7) SEAL GAS LINE SLEEVE EAST OF ENTRY DOOR 8) TJI HANGERS NEED NAILS, MANY TOP AND BOTTOM 9) PROTECT DUCTS AT TOP OF EAST KITCHEN WALL 10) PROTECT WIRE AT EAST MASTER WALL 11) SUPPORT VENT AB'S 90 DEGREE AT MASTER SINK