Inspection History Details
Inspection Status: Approved
Inspection History: STEM WALL/RETAINING WALL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/28/2004 | STEM WALL/RETAINING WALL | Approved | IVRS - Inspection :* | |
| 04/30/2004 | STEM WALL/RETAINING WALL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) OSB SHEATHING REQUIRES NAILS AT 6" ON CENTER AT ALL PANEL EDGES 2) ? BEEN TURN DOWN REQUIRES LINTEL WALL HAS BEARING BEAM OVER OPENING PROVIDE CITY OF TUCSON APPROVED DESIGN FUR LINTEL 3) BEDROOM 16 X 21 REQUIRED 29 SF OF WINDOW PLAN IN ERROR SPECIFIES 4030-PLAN MUST BE REVISED FOR CORRECT WINDOW 4) WATER HEATER T & P LINE MUST EXHAUST OUTSIDE 5) DRYER VENT AND COMBUSTION AIR MUST BE RELOCATED 6) ELECTRIC OUTLETS REQUIRED WITHIN 6 FEET OF DOOR/OPENING AND 12 FEET THERE AFTER 7) HARD WIRED SMOKE DETECTOR REQUIRED IN ADDED B/R SPACE |
|