Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T04CM01107
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/18/2004 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
05/13/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) INSTALL POSITIVE CONNECTION TRUSSES AT BEARING 2) PAHD'S INCORRECTLY INSTALLED ( TOO CLOSE TO CONCRETE EDGE, SPALLING DEVELOPED) 3) RETRO FIT EPOXIED HOLDOWNS 4) INSTALL CROSS BRACING TRUSSES (MAX 25' OF RUN) 5) MAINTAIN 6-12 NAILING ROOF AND 4'-12" EXTERIOR SHEAR 6) ALL NAILS/STAPLES TO BE FLUSH WITH OSB/PLYWOOD 7) INSTALL STRAPS EXTERIOR PLATES AT PLUMBING CUTS 8) STOPPED INSPECTION |