Permit: T04CM01092

Parcel: 136075250

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
05/28/2004 FRAMING Approved IVRS - Inspection :*
05/25/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) "B" TRUSSES NOT BEARING ON BEARING WALL. 4 TRUSS BRACES MISSING. ALSO "C" TRUSSES 2) T & P HAS REVERSE FLOW AND NOT RATED FOR 210. 3) REVISE ELECTRIC PLAN TO AS BUILT 4) 5/SD3 NOT COMPLIED WITH. SHEAR NOT NAILED TO ROOF 5) NAIL GARAGE SHEAR PER SCHEDULE. BLOCK ALL EDGES 6) SHEAR PANEL DAMAGED ABOVE BATHROOM. PEX CANNOT PENETRATE 7) 2- 2 X 4'S REQUIRED UNDER ARCH HEADER 8) SUPPORT/BLOCK GAS HINGE JOINT AT FURNACE
05/21/2004 FRAMING Not ready for Inspection IVRS - Inspection :*/ 1) NEED TRUSS DRAWINGS TO DETERMINE INTERIOR BEARING PTS 2) DON'T USE PEX WIRBO FOR T & P 3) T-FOR GAS LINE IN LAUNDRY, WITH STUB OUT AND CAP REQUIRES A GAS VALVE AND ACCESS 4) AT FRONT DOOR SIX SWITCHES, PLAN SHOWS 3 ? 5) DON'T LOAD ROOF UNTIL BEARING PTS VERIFIED AND SHIMED 6) FINISH STUCCO LATH