Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/17/2004 | FRAMING | Approved | IVRS - Inspection :*/ 1) TRUSS ENGINEERING TURED IN TO FILES | |
| 06/11/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) FIRE STOP CHASE AT PANTRY BY REF 2) ENGINEERED REPAIR REQUIRED ON F2A TRUSS AT STAIR BEARING 2ND TRUSS FROM FRONT ENTRY |
|
| 06/10/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) 6/SD2 BLOCKS NOT NAILED 2) SHIM DOUBLE 2 X POST STAIR 3) SHEAR OSB NOT NAILED NW BEDROOM 4) FIRE BLOCK MISSING HALL TUB 5) WATER HEATER "B" VENT REQUIRES 1" CLEARANCE |
|
| 06/08/2004 | FRAMING | Denied | IVRS - Inspection : A reinspection fee has been assessed for this inspection. Multiple inspection. No truss plan/or repair documents on site see 6/3/04. Secure horizontal runs of wires at 4' on center see 6/3/04 inspection. Wires trapped by ductwork dining room. Truss shear blocks not nailed per 6/SD2. Provide blocking between header and floor per 3/SD2. fireblock missing stair closet. Double 2 x post at stair must bear on bottom plate. Shear osb not nailed n.w. bedroom. Fire block missing hall tub. 1" clearance required at w/h "b" vent 2nd floor. |
|
| 06/07/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) VAPOR BARRIER MISSING EXTERIOR LATH 2) A/C DUCTING TO COMPRESSED 3) ELECTRIC BOX HANGING LOOSE UPSTAIRS 4) CORRECT ALL ITEMS, PREVIOUS AND HAVE TRADES WALK HOUSE 5) STOPPED INSPECTION |
|
| 06/03/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) SEAL ALL PENETRATIONS 2) SEE LAST INSPECTION 3) CLEANOUT LEAKING EAST WALL 4) 90 DEGREE ELBOW MISSING AT PRV 5) FL3 TRUSS, PROVIDE ENGINEER REPAIR 6) EXHAUST FAN IN LAUNDRY MISSING FLAPPER 7) SECURE ROMEX IN LAUNDRY HORIZONTAL RUN 8) STOPPED INSPECTION. HAVE TRADES WALK HOUSE BEFORE RECALL |
|
| 06/01/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) SEAL ALL PENETRATIONS 2) DISSIMILAR METALS NOT ALLOWED TO MAKE CONTACT 3) NO TEST ON DWV'S 4) NO TEST ON WATER LINES 5) BLOCK OUT MECHANICAL 6) EXHAUST FAN IN LAUNDRY ROOM MISSING FLAPPER 7) STOPPED INSPECTION. HAVE TRADES WALK HOUSE BEFORE RECALL, NEXT FAILURE WILL RESULT IN A REFEE |
|
| 05/21/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) LATH NOT INSTALLED |