Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/03/2004 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
| 05/12/2004 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) NEED WASHER DRAIN TRAP-6"-18" AND PAINT ABS PIPES 2) STRAP FHA TOP PLATES WHERE THEY DON'T OVERLAP 3) NEED 1/2" X 8" RED HEADS 48" ON CENTER 4) NAIL OFF EXT. SIDING 5) NOTE: EAST FENCE IS NOT THE PROPERTY LINE |