Permit: T04CM01058

Parcel: 103191070

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
06/24/2004 FRAMING Approved IVRS - Inspection :*
06/21/2004 FRAMING Partial Approval IVRS - Inspection :*/ 1) INSTALL GABLE END BRACING AT 32" CENTER WITH A35'S BOTH ENDS 2) DWV WATER TEST TO GO THROUGH ROOF 3) MAINTAIN 60 POUNDS OR WORKING PRESSURE POTABLE WATER TEST (INSTALL GUAGE)
06/16/2004 FRAMING Denied IVRS - Inspection :/ 1) NEED TRUSS DRAWINGS 2) BATH EXHAUST FAN MISSING 3) PLAN CALLS FOR 3" CLEANOUT HALL BATH 4) WATER TEST DWV 5) MUST HAVE WORKING PRESSURE IN POTABLE WATER TEST 6) INSTALL BANG PLATES AT ELECTRIC AND PLUMBING BORED HOLES 7) PLAN CALLS FOR 60 AMP #6 CU CONDUCTORS 8) PLANS SHOWS 40 AMP #10 WIRE FOR WATER HEATER (CONFLICT) 9) STOPPED INSPECTION