Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 06/24/2004 |
FRAMING |
|
Approved |
IVRS - Inspection :* |
| 06/21/2004 |
FRAMING |
|
Partial Approval |
IVRS - Inspection :*/ 1) INSTALL GABLE END BRACING AT 32" CENTER WITH A35'S BOTH ENDS 2) DWV WATER TEST TO GO THROUGH ROOF 3) MAINTAIN 60 POUNDS OR WORKING PRESSURE POTABLE WATER TEST (INSTALL GUAGE) |
| 06/16/2004 |
FRAMING |
|
Denied |
IVRS - Inspection :/ 1) NEED TRUSS DRAWINGS 2) BATH EXHAUST FAN MISSING 3) PLAN CALLS FOR 3" CLEANOUT HALL BATH 4) WATER TEST DWV 5) MUST HAVE WORKING PRESSURE IN POTABLE WATER TEST 6) INSTALL BANG PLATES AT ELECTRIC AND PLUMBING BORED HOLES 7) PLAN CALLS FOR 60 AMP #6 CU CONDUCTORS 8) PLANS SHOWS 40 AMP #10 WIRE FOR WATER HEATER (CONFLICT) 9) STOPPED INSPECTION |