Permit: T04CM01058

Parcel: 103191070

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
06/07/2004 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
06/02/2004 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) GARAGE SOUTH HOLDOWNS 2) ON SOUTH SIDE OF GARAGE WRONG LOCATION-MUST BE PER PLAN 2) BEDROOM 3 SOUTH HOLDOWN WRONG LOCATION 3) EAST WALL TWO SOUTH HOLDOWNS WRONG LOCATION 4) 2/10 NOT COMPLIED WITH 5) GARAGE SHEAR MUST BE CONTINOUS FLOOR TO ROOF 6) COMPLY WITH ALL PRIOR INSEPCTION ITEMS. NEXT FAILURE WILL BE CHARGED A REINSPECTION FEE
05/26/2004 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) STRAP ACCROSS GAP IN SHEATHING GARAGE OSB AT 8' S.W. 2) INSTALL DRAG STRUTS 32" SPACING SEE DETAIL 2-10 3) CROSS-BRACE ROOF TRUSSES EACH END AND MAXIMUM 25' OF RUN 4) HOLDOWNS TO BE WITHIN 4" OF SPECIFIED LOCATION ON PLAN 5) EXCESSIVE SPALLING ON SOME PAHD'S-INSTALL ALTERNATES-BOLTS ON SHEARWALLS 5-16" ON CENTER SPACING-BOTTOM TO PLATES 7) BOLTS ON SHEARWALLS 3-32" ON CENTER SPACING BOTTOM PLATES 8) SHEARWALL 5 REQUIRED 10D NAILS AT 4"-12" SPACING 9) AT GARAGE WALL SHEAR WALL 3, INSTALL A.34'S BOTTOM CHORD TRUSS TO TOP PLATE
05/20/2004 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
05/14/2004 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) ITEMS NOT CORRECTED
05/11/2004 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) HOLDOWNS INCORRECTLY INSTALLED AND OR WRONG LOCATIONS 2) NAILS TOP AND BOTTOM WIND BRACING 3) NAILS SET TO DEEP SHEATHING 4) STRAP PLB EXTERIOR PLATES 5) NEED LADDER TO INSPECT ROOF 6) SHEARWALLS INCOMPLETE 7) STOPPED INSPECTION
05/10/2004 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) HOLDOWNS WRONG LOCATION 2) NAIL PATTERNS NOT MAINTAINED 3) STOPPED INSPECTION 4) RE-SUBMIT PLOT PLAN WITH SETBACK CHANGES TO 3'-2" (CHANGED AFTER APPROVAL)