Permit: T04CM01057

Parcel: 103190890


Addresses:

2541 W AZTLAN CT

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
07/17/2004 FRAMING Approved IVRS - Inspection :*
07/14/2004 FRAMING Partial Approval IVRS - Inspection :*/ 1) COMPLETE NUMBERS 5, 6, 9 AND 10 2) SHIM SOLIDLY AT BEARING ABOVE HEADERS
06/25/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) INSTALL PLATFORM A/C HEATER ROOM 2) HORIZONTAL JOINTS ARE TO BE TONGUE AND GROOVE FOAM FOR LATH 3) PLAN CALLS FOR #6 CU TO A/C UNIT EXTERIOR 4) INSTALL GAUGE FOR POTABLE WATER PRESSURE MINIMUM 60 POUND 5) HAVE 03050 REMOVED FROM PERMIT CARD AND CITY COMPUTER SYSTEM 6) MECH PLANS SHOWS HEAT PUMP-HEAT STRIP (NEED ELECTRIC CALC'S FOR UNIT USED) 8) NO TEST DWV; SHIM SOLIDLY AT BEARING ABOVE HEADERS 9) INSTALL HINGE BRACING GABLE ENDS MAX-32" ON CENTER SPACING 10) WITH A3.5'S BOTH ENDS H2.55 11) STOPPED INSPECTION