Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T04CM01057

Parcel: 103190890


Addresses:

2541 W AZTLAN CT

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
05/20/2004 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
05/13/2004 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) 2 NAILS TOP AND BOTTOM WIND BRACING 2) INSTALL NUTS EXTERIOR WALL BOTTOM PLATES 3) INSTALL HOLDOWNS PER PLAN 4) NAILS/STAPLES TO BE FLUSH WITH SHEATHING 5) INSTALL RETRO FIT EXPOXIED HOLDOWNS WHERE PAHD'S INCORRECTLY INSTALLED (SPALLING OF CONCRETE EXCESSIVE) 6) INSTALL WIND BRACING ALL CORNERS EACH WAY AND MAXIMUM, 25' OF RUN (SAME FOR CROSS BRACE TRUSSES) 7) NEED LADDER TO INSPECT ROOF