Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T04CM01053
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/27/2004 | FRAMING | Approved | IVRS - Inspection :* | |
06/08/2004 | FRAMING | Partial Approval | IVRS - Inspection :*/ 1) HAVE TRUSS REPAIR DOCUMENTS STAMPED BY PLAN CHECK CITY OF TUCSON | |
05/28/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) SEE ROOF NAIL INSPECTION 2) CANCELLED ON SITE |
|
05/27/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) T1 JACK TRUSSES MODIFIED-PROVIDE ENGINEER REPAIR 2) FIRE BLOCK MISSING AT KITCHEN 3) FIRE BLOCK LANDING AREA AND CHASES 4) FIRE BLOCK MISSING RIGHT SIDE M/BR WINDOW 5) FIRE BLOCK MECH CHASES 6) SEAL ALL PENETRATIONS FROM FIRST TO 2ND FLOOR AND INTO ATTIC 7) SEAL ALL LATH PENETRATIONS FROM INSIDE 8) STAIR LEDGER NOT NAILED |
|
05/26/2004 | FRAMING | Denied | IVRS - Inspection : There is no plan or job inspection card on site.| 925*/ 1) NO PLAN OR PERMIT ON SITE |