Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/24/2004 | FRAMING | Approved | IVRS - Inspection :* | |
| 06/23/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) #2 AND 3 NOT DONE FROM PREVIOUS INSP. |
|
| 06/17/2004 | FRAMING | Not ready for Inspection | IVRS - Inspection :*/ 1) FROM EXT. SHEATHING INSP. MISSED P.A. S. WALL, NEED LOCATION #-INSTALL ON S. WALL NO NAILS STUD TO H.D., PLAN CALLS FOR 4 PAHD42 2) SHEAR WALLS NOT TRANSFERED TO ROOF 3) #3 SHEARS MISSING AT BAY WINDOW DINING 4) TRUSS GUSSETS NOT POSITIONED ON TRUSS JOINTS MST. BEDROOM AND GARAGE CHECK THEM ALL 5) DIVERTER STUD NORTH SHOWER NOTCHED TOO DEEP 6) LEAVE TRUSS DRAWINGS ON SITE, CHECK ALL LATERAL BRACING AND 3 PT BEARING 7) KITCHEN OPT. BASIC PLAN SHOW DIAGONAL WALL, OPTION8) KEEP PEX 12" FROM LIGHT CNAS KIT 9) GAS, DWV, POTABLE WATER OK 10) MISSING COMB, DUCT GARAGE 11) SMALL GIRDER GARAGE GUSSET PLATE NOT ALIGNED WITH JOINT |