Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T04CM01051

Parcel: 108163730

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
06/24/2004 FRAMING Approved IVRS - Inspection :*
06/23/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) #2 AND 3 NOT DONE FROM PREVIOUS INSP.
06/17/2004 FRAMING Not ready for Inspection IVRS - Inspection :*/ 1) FROM EXT. SHEATHING INSP. MISSED P.A. S. WALL, NEED LOCATION #-INSTALL ON S. WALL NO NAILS STUD TO H.D., PLAN CALLS FOR 4 PAHD42 2) SHEAR WALLS NOT TRANSFERED TO ROOF 3) #3 SHEARS MISSING AT BAY WINDOW DINING 4) TRUSS GUSSETS NOT POSITIONED ON TRUSS JOINTS MST. BEDROOM AND GARAGE CHECK THEM ALL 5) DIVERTER STUD NORTH SHOWER NOTCHED TOO DEEP 6) LEAVE TRUSS DRAWINGS ON SITE, CHECK ALL LATERAL BRACING AND 3 PT BEARING 7) KITCHEN OPT. BASIC PLAN SHOW DIAGONAL WALL, OPTION8) KEEP PEX 12" FROM LIGHT CNAS KIT 9) GAS, DWV, POTABLE WATER OK 10) MISSING COMB, DUCT GARAGE 11) SMALL GIRDER GARAGE GUSSET PLATE NOT ALIGNED WITH JOINT