Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/05/2005 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 03/28/2005 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) CAULK BASE OF TUB AND TOILET 2) NEED COMB/RELIEF H20 HEATER TOP OF DOOR ALSO 3) CANNOT HAVE EXPOSED BULBS CLOSET LIGHTS 4) NO POWER KITCHEN COUNTER TOP OUTLET RIGHT SIDE SINK 5) INSTALL ELECTRIC COVER PLATE EXTERIOR NORTH SIDE 6) RAISE DISHWASHER DRAIN AND SECURE TO UNDERSIDE OF COUNTER TOP 7) KITCHEN CABINTRY CHANGED NEED ADDITIONAL (OUTLETS ELECTRIC) 8) INSTALL GAS COCK AND FLEX LINE CAPPED GAS DRYER LOCATION 9) HOT WIRES ELECTRIC IMPROPERLY COLOR CODED AT A/C BOX ON ROOF 10) RAISE H20 HEATER VENT 12" ABOVE ROOF PARAPET 11) STOPPED INSPECTION |