Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 06/07/2004 |
ELECTRIC - INTERMEDIATE |
|
Approved |
IVRS - Inspection :*/ OK ROUGH |
| 06/01/2004 |
ELECTRIC - INTERMEDIATE |
|
Not ready for Inspection |
IVRS - Inspection :*/ 1) OUTLETS TO BE SPACED PER 210-52. 2) WE HAVE CONDUCTOR OVER FILL IN BOX. 3) SECURE NM CABLE WITHIN 12" OF BOXES. 4) FINISH BOX MAKE-UP AND PANELS. 5) CONDUCTORS TO EXTEND 6" BEYOND BOX. 6) PROTECT CABLES AT STUDS. 7) APPROVED FITTINGS REQUIRED AT BOXES. 8) TIGHTEN LOOSE FITTINGS. 9) BLDG INSP. TO CHECK FOR FIRE WALL PENETRATIONS. |
| 04/06/2004 |
ELECTRIC - INTERMEDIATE |
|
Not ready for Inspection |
IVRS - Inspection 0000* |