Permit: T04CM01030

Parcel: 122173100

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
06/07/2004 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*/ OK ROUGH
06/01/2004 ELECTRIC - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*/ 1) OUTLETS TO BE SPACED PER 210-52. 2) WE HAVE CONDUCTOR OVER FILL IN BOX. 3) SECURE NM CABLE WITHIN 12" OF BOXES. 4) FINISH BOX MAKE-UP AND PANELS. 5) CONDUCTORS TO EXTEND 6" BEYOND BOX. 6) PROTECT CABLES AT STUDS. 7) APPROVED FITTINGS REQUIRED AT BOXES. 8) TIGHTEN LOOSE FITTINGS. 9) BLDG INSP. TO CHECK FOR FIRE WALL PENETRATIONS.