Permit: T04CM01028

Parcel: 113083100

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
04/21/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
1) #4-#6 NEED A TENSION # PLATE BOLTS AT INTERMEDIATE
2) FIRE RATED PLYWOOD INSTALLED, AREAS CLOSER THAN 3'-0" TOGETHER-OK
3) NEED REVISION TO SERVICE EQUIPMENT 4 METERS, ONE IS FOR COMMON AREA
4) BOND/GRD PER NEW DAWING
5) UNIT # 1 2 OTHER PERMITS OK FOR ALL 3 PERMITS PLEASE CALL IN OTHER TWO INSPECTION
6) OK TO LATH
04/15/2005 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) NO PLANS/PERMIT
02/08/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PORCH POST TO BEAM HARDWARE USE 10D COMMON NAILS, FILL ALL HOLES
2) TWO PA STRAPS, NEED ALTERNATE REPLACEMENT DO TO SPALLING
3) SMALL PIECES OF OSB AT RIDGE, TURNED WRONG WAY, TO NARROW BLK. JOINTS
4) DETAIL AT FRONT DOOR BEAM TO BEAM WITH H.V. TYPE INSIDE FLANGE HANGER NOT ON PLAN CARRIES 3 TRUSS LOAD, INSIDE FLANGE NAILING ARE 16D COMMONS, VERIFY NAILS AND NEED DETAIL
5) PORCH LEDGERS NOT NAILED, EDGE OF PORCH DECK AGAINST WALL REQUIRES BLOCKS
6) MISSING PLATE BOLTS AND NUTS, THRU-OUT
7) JOINT TRUSS TO TOP PLATE, OK STUD TO 1ST TOP PLATE OK, THE TWO TOP PLATES ARE NOT TIED TOGETHER
8) NAIL OSB TO VERT LEG OF TRUSS. LEAVE TRUSS DRAWINGS ON SITE
9) OSB JOINT NOT TIED TOGETHER
10) NOTE: PER ZONING BLDG SETBACKS ARE 4'-0"
11) 1/2" FIRE-RATED PLYWOOD REQUIRED ON PORCH ENDS-PARAPETS
12/21/2004 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
The setbacks are not per plan.| 105*
1) HOUSES ARE LESS THAN 6 FEET APART. NO INSPECTIONS WILL BE MADE UNTIL YOU GET SITING RESOLVED AND APPROVED BY DEVELOPMENT SERVICES PLAN CHECK
12/17/2004 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
12/13/2004 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*