Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/19/2004 | FRAMING | Approved | IVRS - Inspection :* | |
| 05/18/2004 | FRAMING | Partial Approval | IVRS - Inspection :*/ 1) SEE LAST INSPECTION | |
| 05/17/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) NO TEST ON WATER LINES 2) ROOFING MATERIAL TO CLOSE TO WATER HEATER B-VENT NEED 1" CLEARANCE 3) FRAMING WILL BE APPROVED WHEN EVERYTHING IS COMPLETE 4) OVER NOTCHED 2 X 6 STUD 5) FREEZE BOARDS NOT INSTALLED AT BACK PATIO |
|
| 05/13/2004 | FRAMING | Partial Approval | IVRS - Inspection :*/ 1) FREEZE BOARDS NOT INSTALLED AT BACK PATIO 2) FIRE BLOCK CHASE INTO ATTIC SPACE 2ND FLOOR FOR WATER HEATER FLUE AND PROVIDE 1" CLEARANCE FROM COMBUSTIBLES 3) FIRE BLOCK ALL MECH CHASES, INTO ATTIC SPACE 2ND FLOOR 4) PROVIDE WATER TEST FOR WATER LINE |