Permit: T04CM01021

Parcel: 140323440

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T04CM01021

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
05/19/2004 FRAMING Approved IVRS - Inspection :*
05/18/2004 FRAMING Partial Approval IVRS - Inspection :*/ 1) SEE LAST INSPECTION
05/17/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) NO TEST ON WATER LINES 2) ROOFING MATERIAL TO CLOSE TO WATER HEATER B-VENT NEED 1" CLEARANCE 3) FRAMING WILL BE APPROVED WHEN EVERYTHING IS COMPLETE 4) OVER NOTCHED 2 X 6 STUD 5) FREEZE BOARDS NOT INSTALLED AT BACK PATIO
05/13/2004 FRAMING Partial Approval IVRS - Inspection :*/ 1) FREEZE BOARDS NOT INSTALLED AT BACK PATIO 2) FIRE BLOCK CHASE INTO ATTIC SPACE 2ND FLOOR FOR WATER HEATER FLUE AND PROVIDE 1" CLEARANCE FROM COMBUSTIBLES 3) FIRE BLOCK ALL MECH CHASES, INTO ATTIC SPACE 2ND FLOOR 4) PROVIDE WATER TEST FOR WATER LINE