Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T04CM01018

Parcel: 141305770


Addresses:

10564 E OAKBROOK ST


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T04CM01018

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
05/04/2004 FRAMING Approved IVRS - Inspection :*
04/30/2004 FRAMING Not ready for Inspection IVRS - Inspection :*/ 1) LOOSE HIP JACK GARAGE 2) NEED DWV TEST 3) BROKEN CRIPPLE IN UTILITY ROOM UNDER WINDOW 4) WATER TEST OK 5) KITCHEN DINING ROOM BANG PLATES, ? FIX STUDS 6) ENTRY LIVING ROOM FHA STRAP AT BOTTOM PLATE, BANG PLATE AT TOP 7) CHECK WATER SERVICE FOR STAPLE TOP PL. 8) FRONT BEDROOM SECURE INTERIOR FRAMING 9) MOVE PEX 12" FROM HALL CAN 10) BANG PLATES DOUBLE LAV. 11) ZERO GAS PRESSURE TEST 12) SECURE AND BP LINE