Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/23/2005 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 06/22/2005 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) SAME AS INSPECTION OF 7/21/04 |
|
| 07/21/2004 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 07/19/2004 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 06/14/2004 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :*/ 1) NOT READY PER OWNER REPRESENTATIVE | |
| 06/10/2004 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) BREAKERS USED IN SUB-PANEL OTHER THAN THOSE SPECIFIED BY LISTING 2) INSTALL RANGE HOOD 3) KITCHEN ELECTRIC OUTLETS NOT PER PLAN 4) BASEBOARD HEATERS CANNOT BE INSTALLED UNDER ELECTRIC OUTLETS 5) GFCI'S NOT WORKING 6) SEAL AROUND BASE OF TOILET AND TUB 7) INSTALL ALL LIGHTS, SWITCHES, OUTLETS, ETC... 8) APPEARS ALL BASEBOARD HEATERS ARE NOT ADDED TO ELECTRIC CALC'S 9) NEED VERIFICATION OF ELECTRIC PANEL GROUNDING 10) INSTALL SMOKE DETECTORS IN HALLS LEADING TO BEDROOMS 11) POST ADDRESS NUMBERS ON UNITS VISIABLE FROM STREET 12) INSTALL ANTI-SIPHON HOSE BIBS 13) SEAL AROUND EVAP COOLER PENETRATION INTO UNIT 14) INSTALL FUSED DISCONNECT EVAP COOLER 15) PERMANENTLY LABEL ALL CIRCUITS SERVED IN PANEL BOXES (ELECTRIC) 16) PAINT EXPOSED PLUMBING VENTS ON ROOF 17) INSTALL NO-LOX ALUMINIUM CONDUCTORS 18) ELIMINATE ALL WIRING UNUSED IN PANEL BOXES 19) NEED VERIFICATION OF ELECTRIC CONDUIT UNDERGROUND 20) RENTAL UNITS NEED VERIFICATION OF LICENSED/SUB-CONTRACTOR 21) STOPPED INSPECTION |
|
| 03/25/2004 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection 0000* |