Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 06/30/2004 |
PLUMBING - INTERMEDIATE |
|
Approved |
IVRS - Inspection :* |
| 06/02/2004 |
PLUMBING - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection :*/ SUPPORTS OK. CLOSET FLANGES TO BE FLUSH WITH WASTE PIPE AT STOOLS PRIOR TO SETTING STOOLS - NEED TO VERIFY THIS. / 0350 - 60 PSI TEST ON 3" FROM METER TO SEVEN ROOF TOP UNITS PER PLAN PARTIAL APPROVAL. 1) NEED TO SEE 10 PSI TEST WHEN VALVES ARE IN PLACE AND UNITS HOOKED UP. 60 PSI TEST ON 2" SYSTEM FROM METER TO TWO HANGING SPACE HEATERS AND TWO ROOF TOP UNITS PARTIAL APP. 2) NEED TO SEE 10 PSI TEST WHEN VALVES ARE IN PLACE AND UNITS HOOKED UP. |