Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 06/30/2004 |
FRAMING |
|
Approved |
IVRS - Inspection :* |
| 06/02/2004 |
FRAMING |
|
Partial Approval |
IVRS - Inspection :* 1) REVISE DETAIL 1/A1.1 FOR AS-BUILT(NO TOP TRACK OR STUDS ONLY 3" SLIP W/ NO SCREWS). 2) ANY FIRE BARRIER WILL NEED TOP TRACK @ PURLES FOR SHEET ROCK TO FLY TO DECK. |