Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T04CM00925

Parcel: 116035940

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
04/07/2004 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
04/06/2004 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection 0000*/ 1) NO CHANGE ON CLIP FROM 1/5/04
04/05/2004 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection 0000*/ 1) OK TO DRY 2) TRUSSES A1, A1GE MISSING BOTTOM CHORD BRACING AT 5-5-8 ON CENTER 2) PROVIDE SHEAR WALL AND HOLDOWN SCHEDULE FOR 1 1/2 ? W/5' EXTENSION AT SHEAR WALL 5 3) ENTRY GLB HANGER NOT IN 4) HOLDOWN MUST BE ON FULL LENGTH DOUBLE STUDS SOUTH END OF EAST SHEAR WALL