Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/24/2004 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 06/17/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) NAILS/STAPLES TO BE SET FLUSH WITH OSB/PLYWOOD 2) MAINTAIN 6" -12" PATTERN #3 SHEARWALL NAILING 3) STRAP PLB. CUTS EXTERIOR PLATES 4) MOVING EXTERIOR WIND BRACING HITTING PLB. PIPING 5) INSTALL 2 NAILS TOP AND BOTTOM AND ONE NAIL EACH STUD WIND BRACING 6) SEE DETAIL 2/10 AND COMPLY 7) NEED LADDER TO INSPECT ROOF 8) NAIL BLOCKING THROUGH ROOF SHEATHING BETWEEN TRUSSES AT BEARING 9) STOPPED INSPECTION 10) SUPER TO WALK JOBS PRIOR TO REQUESTING INSPECTIONS AND CORRECT ITEMS |