Inspection Status: Denied
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/10/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO TEST AT DWV 2) PROTECT ALL PLUMBING |
|
| 01/10/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 12/21/2004 | FRAMING | Partial Approval | IVRS - Inspection :* 1) OK TO DRY WALL EXCEPT AROUND BATHROOMS |
|
| 11/12/2004 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
| 11/08/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) 2 X 8 RAFTERS HAVE TAILS CUT TO 2" ON ? 2) HAVE PLAN REVISED TO CHECK DBL 2 X 8 RIDGE BEAM BEARING 16 LF BETWEEN GLB AND BEARING WALL 3) ELECTRIC PANEL NOT READY 4) INSULATE ALL DUCT TRANSITIONS WITH R-6 INSUALTION AND VAPOR BRRIER 5) SHIM HEADERS TO TRIMMERS 6) SUPPORT AIR REGISTERS 3 SIDES 7) FIRE BLOCK FURR OUT |