Permit: T04CM00844

Parcel: 111063100

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Permit Number - T04CM00844

Inspection Description - MECHANICAL - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
05/11/2005 MECHANICAL - FINAL Approved IVRS - Inspection :*
05/10/2005 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
05/06/2005 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE MINIMUM 3 SCREWS IN ALL JOINTS OF WATER HEATER VENT CONNECTOR AND KITCHEN EXHAUST
2) TIGHTEN FITTINS ON GAS FLEX CONNECTORS. BLOCK AND CLAMP CONDENSATE DRAIN LINES ON ROOF AND PAINT WITH LATEX PAINT
3) PROVIDE ELECTRIC DISCONNECTS AND FUSES
4) FIREPLACE VENTS MUST BE MINIMUM 3' ABOVE ROOF TO BOTTOM OF CAP