Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
Permit Number - T04CM00843
Inspection Description - MECHANICAL - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/11/2005 | MECHANICAL - FINAL | Approved | IVRS - Inspection :* | |
| 05/10/2005 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 05/06/2005 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) INSTALL KITCHEN EXHAUST 2) PROVIDE MINIMUM 3 SCREWS IN ALL JOINTS ON WATER HEATER VENT CONNECTORS INCLUDING DRAFT DIVERTERS 3) PROVIDE SCREWS IN KITCHEN EXHAUST DUCTS 4) TIGHTEN FITTINGS ON GAS FLEX CONNECTORS 5) BLOCK AND CLAMP CONDENSATE DRAINS ON ROOF AND PAINT WITH LATEX PAINT 6) PROVIDE ELECTRIC DISCONNECTS AND FUSES 7) FIREPLACE VENTS MUST BE MINIMUM 3' ABOVE ROOF TO BOTTOM OF CAP |