Inspection History: ELECTRIC - UNDERGROUND

Date Description Inspector Results Comments
05/11/2004 ELECTRIC - UNDERGROUND Approved IVRS - Inspection :*
04/30/2004 ELECTRIC - UNDERGROUND Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) EXPOSE COLUMN FOOTINGS TO A DEPTH OF 12" 24" WIDE 2) EXPOSE ELECTRIC CONDUIT AT EACH END 3) EXPOSE ALL OF GAS LINE AND PROVIDE A MINIMUM OF 10 PSI PRESSURE TEST. DISCONNECT FROM METER 4) ROOF RAFTERS MUST BE AT 12" O.C. 5) EXPOSE ALL PLUMBING 6) UNDERSIZE RIDGE BEAM AT FRONT PORCH SE CORNER 7) PLUMBING AT SLAB REQUIRES SLEEVES 8) SINK NOT PROPERLY VENTED 9) OUTSIDE ELECTRIC OUTLETS MUST BE GFCI PROTECTED