Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 04/21/2004 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 04/19/2004 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) SOUTH END OF PATIO ROOF NOT NAILED OFF 2) 1 ROW MISSING AT S.W. HIP 3) NAIL OFF H2.5 AT ENTRY TRUSS 4) NEED RED HEADS AT ENTRY COLUMN AND OPEN PATIO COLUMN FOR A.B. INSPECTION |
| 04/14/2004 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) NO PLANS ON SITE |
| 04/13/2004 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) CLIP FRONT ENTRY HDR. CAPPLES KING STUD 2) RENAIL PERIMETER BLOCKS BETWEEN TRUSSES RE-CHECK ROOF 3) PROVIDE DBL KINGS FOR DBL TRUSS AT SOUTH WALL 4) STRAP AND CLIP BEAM TO WALL AT REAR WALL |