Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 04/07/2004 |
PLUMBING - INTERMEDIATE |
|
Approved |
IVRS - Inspection 0000* |
| 03/11/2004 |
PLUMBING - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0999*/ 1) GAS PRESSURE TEST OF 6' OF 3/4" GAS LINE ON WEST SIDE OF HOUSE ONLY OK. 2) YOU MUST PROVIDE PERMIT/PROOF OF INSP FOR NEW GAS PACK ON ROOF. 3) PEX PLBG NOT ALLOWED TO BE EXPOSED ON EXTERIOR OF HOUSE. 4) LOCATION OF NEW WTR HTR IS NOT PER APPROVED PLAN. BUILD TO PLAN OR REVISE PLAN TO BE AS BUILT AND HAVE APPROVED. 5) GAS LINE MUST BE ELECTRICALLY BONDED. |