Permit: T04CM00696

Parcel: 136216870

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
05/19/2004 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
05/17/2004 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) RECHECK SHEAR NAILING FOR NAILS BEING SHOT TO DEEP AT PATIO 2) TC CLIP NAILS SHOULD BE AT INSIDE OF SLOTS 3) CLIPS ABOVE PATIO DOOR ON TRUSSES MUST BE SLIDE CLIPS-NOT H2.5'S
05/12/2004 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) ONE ROW OF ROOF NAILING MISSED 2) MIS-NAILED T.C. CLIPS 3) NEED TRUSS CALC'S TO DETERMINE IF TRUSSES SHOULD BE BEARING ON PATIO DOOR WALL 4) RENAIL SHEAR WHERE NAILS ARE SHOT TOO DEEP 5) STRAP EAST END OF ENTRY GABLE TRUSS DOWN TO KING