Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date |
Description |
Inspector |
Results |
Comments |
| 04/01/2004 |
PLUMBING - ROUGH, SOIL |
|
Approved |
IVRS - Inspection 0000*/ CORRECTIONS MADE OK. OK TO COVER. |
| 03/30/2004 |
PLUMBING - ROUGH, SOIL |
|
Partial Approval |
IVRS - Inspection 0000* |
| 03/29/2004 |
PLUMBING - ROUGH, SOIL |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) HORIZONTAL BY HORIZONTAL CHANGE OF DIRECTION TO BE THRU WYE BRANCH OR EQUIVELENT. 2) A C.O. EXTENSION TO BE THRU A WYE BRANCH OR EQUIVILENT. 3) CHECK URINAL HIEGHT AND C.O. LOCATION. 4) A BLAKE TEE MAY NOT BE INSTALLED IN A HORIZONTAL POSITION BELOW GRADE. |