Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/02/2004 | MECHANICAL - FINAL | Approved | IVRS - Inspection :* | |
| 08/02/2004 | MECHANICAL - FINAL | Not ready for Inspection | IVRS - Inspection :ATTIC FURNACES, COME OUT OF TFURNACE WITH SINGLE WALL FLUE, PAST THE FURNACE COVER THE TRANSITION TO DBL WALL, REPLACE DAMAGE INSPECTION COVER ON ONE FURNACE | |
| 07/29/2004 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |