Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING PRE-SLAB
Permit Number - T04CM00649
Inspection Description - BUILDING PRE-SLAB
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/16/2004 | BUILDING PRE-SLAB | Approved | IVRS - Inspection 0000* | |
03/12/2004 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000*/ 1) OK TO POUR WILL REQUIRE POST TENSION REVISION FOR THIS HOUSE | |
03/11/2004 | BUILDING PRE-SLAB | Not ready for Inspection | IVRS - Inspection 0000*/ 1) RETEST PLBG NEW FITTINGS ADDED. 2) NO POST TENSION SPECIAL INSPECTION REPORT. 3) PLBG IS WRAPPED. |