Permit: T04CM00625

Parcel: 140374210


Addresses:

7067 S GULL LN

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
05/14/2004 FRAMING Approved IVRS - Inspection :*
05/12/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) DWV'S OK, WATER LINES OK 2) GAS TEST OK 4) INTERIOR HOLDOWN NOT INSTALLED
05/11/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) INTERIOR HOLDOWN MISSING 2) 2 STUDS MISSING UNDER BEAM 3) FIRE BLOCK MISSING AT ENTRY 4) CRIPPLE MISSING UNDER WINDOW 5) FIREBLOCK 2ND FLOOR CHASE 6) DRYER VENT NOT NAIL PROTECTED 7) FIREBLOCKS MISSING UPSTAIRS
05/07/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) GAS TEST WAS AT 25 PSI READING, I LET AIR OUT, AIR COMPLETELY OUT AT 19 PSI ON GUAGE 2) NAIL PROTECT PLUMBING WITHIN 1 1/2" FROM EDGE OF STUD 3) FIRE BLOCK MISSING AT FRONT ENTRY 4) FIREBLOCK CHASE AT 2ND FLOOR 5) NAIL PROTECT DRYER VENT 5) INSULATE BEHIND TUB 6) FIRE BLOCKS MISSING AT STAIR AREA 7) DWVS' NOT HOLDING WATER AT 2ND FLOOR 8) PROVIDE 2 MORE 2 X'S AT KITCHEN BEAM 9) RAT RUN CUT AT KITCHEN 10) HORINZONTAL RUNS ON WATER LINES MUST HAVE THE 1 1/2" CLEARANCE FROM EDGE