Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T04CM00601
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/29/2004 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
03/26/2004 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection 0000* | |
03/25/2004 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | 1) A-2 TRUSSES DRAWING NOT IN CALC'S, A-3 TRUSSES DRAWING NOT IN CALC'S 2) DOUBLE 2 X 4 UNDER GARAGE GIRDER TRUSS 3) NEED A HEADER SCHEDULE 4) 3' STRAPS AT GARAGE (DRAG STRUTS) |