Permit: T04CM00583

Parcel: 140106100

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
05/06/2004 FRAMING Approved IVRS - Inspection :*
04/26/2004 FRAMING Partial Approval IVRS - Inspection :
See detailed listing on site.| 999*/ 1) WILL NEED SPECIAL INSPECTION PAPERWORK ON CUT THROUGH POST TENSION SLAB. (CABLES EXPOSED)
04/22/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) SHEARWALL TRANSFER TO CARRY ACCROSS DOUBLE TOP PLATES TO UNDERSIDE OF JOISTS ON TRUSSES 2) WILL NEED SPECIAL INSPECTION FROM ENGINEER ON SLAB CUTS/REPAIRS 3) UNCOVER ALL PIPING REPAIRED UNDER SLAB
04/13/2004 FRAMING Denied IVRS - Inspection 0999*/ 1) INSTALL WINDOWS 2) NO TEST DWV 3) REFEE DUE
04/12/2004 FRAMING Denied IVRS - Inspection 0999*/ 1) USE 10D NAILS JOIST/BEAM HANGERS 2) GARAGE SHEAR OSB TO CARRY TOO UNDERSIDE OF FLOOR JOISTS FIRE BLOCK KITCHEN AT EACH END NEAR GLB 3) NO TEST DWV; INSTALL POSITIVE CONNECTION BEAMS AND JOISTS TO BEARING. NO PLANS. STOPPED INSPECTION
04/09/2004 FRAMING Denied IVRS - Inspection 0999*/ 1) USE 10D NAILING JOIST HANGERS ETC. 2) NO TEST DWV 3) STOPPED INSPECTION