Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/22/2004 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 04/19/2004 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection 0935*/ 1) NAIL PROTECT ELECTRICAL PER PLAN/CODE 2) RE-FEE 3) NAIL PROTECT DRYER VENT | |
| 04/16/2004 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection 0999*/ 1) UFER CUT, NAIL PROTECT ELECTRICAL WITHIN 1 1/4" FROM EDGE OF STUDS | |
| 04/14/2004 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection 0999*/ 1) PLUMBING AND GAS TEST OK 2) NEXT FAILURE WILL BE RE-FEE 3) SEE LAST INSPECTION | |
| 04/13/2004 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection 0999*/ 1) OVERSPAN AT 2 X 6 GARAGE WALL 2) BLOCK ALL MECHANICAL 3) CONDENSATE LINES NOT HOOKED UP 4) NAIL PROTECT ELECTRIC AT KITCHEN 5) SEAL ALL PENETRATION INTO ATTIC SPACE 6) NAIL PROTECT DRYER VENT FROM CLOSET SIDE 7) BLOCK HI AND LOW COMBUSTION RELIEF |