Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 04/21/2004 |
PLUMBING - INTERMEDIATE |
|
Approved |
|
| 04/02/2004 |
PLUMBING - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection 0000*/ SUBJECT TO APPROVED PLAN RED LINES ON JOB. |
| 04/01/2004 |
PLUMBING - INTERMEDIATE |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ NOT TO CODE. |
| 03/29/2004 |
PLUMBING - INTERMEDIATE |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) EXTENT OF PLAN IS TO PROVIDE ½" CW TO ICEMAKER BOX. 2) RE-ROUGH LAV. FOR ADA. 3) R.O. DRAIN MAY NOT BE DIRECTLY CONNECTED WITH A SADDLE FITTING TO A CONDENSATE DRAIN TIED DIRECTLY TO A VENT STACK. 4) PVC CONDENSATE DRAIN MAY NOT BE DIRECTLY CONNECTED TO VENT STACK. 5) WTR HTR REQUIRES EXPANSION TANK AND OPENABLE T&P RELIEF DRAIN TO AN APPROVED LOCATION. WHAT ABOUT PLAN AND PAN DRAIN? |