Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T04CM00559
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/17/2004 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
09/15/2004 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :*1)SOIL WATER TEST IS OK 2)OVERHJEAD WATER DISTRIBUTION IS OK 3)WASTE & VENT SYSTEM IS OK 4)OK FOR DRYWALL | |
09/14/2004 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : 1) TRAP ARM FRO LAVATORY NOT TO CODE FOR MASTER BATH. 2) RETEST SYSTEM |
|
09/08/2004 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999*/1)SHALL PROVIDE MIN 3" VENT THEN ROOF 2)SHALL PROVIDE 2" P-TRAP FOR KITCHEN SINK. TRAP SHALL BE THE SAME SIZE AS DRAIN SERVED 3)LAVATORY DRAINS AND STUDOR? VENT LOCATION NOT TO CODE |