Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T04CM00546

Parcel: 138150320


Addresses:

24 E CALLE SEVILLA


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T04CM00546

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
03/19/2004 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
03/18/2004 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) SHEAR PANEL ENDS AND EDGES REQUIRE NAILING AT ENDS AND EDGES MAXIMUM SPACING 6" ON CENTER 2) SOUTH EAST CORNER SHEAR PANEL CUT IN HALF EITHER REPLACE WITH FULL PANEL OR INSTALL 2 X BLOCKING FOR EDGE NAILING 3) SOUTH WALL NOT CLIPPED 4) KING STUDS NOT CLIPPED 5) GARAGE WEST WALL NOT CLIPPED 6) TWO ROOF PANELS NOT NAILED