Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 03/19/2004 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 03/18/2004 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) SHEAR PANEL ENDS AND EDGES REQUIRE NAILING AT ENDS AND EDGES MAXIMUM SPACING 6" ON CENTER 2) SOUTH EAST CORNER SHEAR PANEL CUT IN HALF EITHER REPLACE WITH FULL PANEL OR INSTALL 2 X BLOCKING FOR EDGE NAILING 3) SOUTH WALL NOT CLIPPED 4) KING STUDS NOT CLIPPED 5) GARAGE WEST WALL NOT CLIPPED 6) TWO ROOF PANELS NOT NAILED |