Permit: T04CM00527

Parcel: 137322790


Addresses:

5523 S SWIRES RD

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
06/16/2004 FRAMING Approved IVRS - Inspection :*
06/14/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) SECURE ROMEX WITHIN 12" BOXES 2) INSTALL BANG PLATE NAIL PROTECTING ELECTRIC HOLES IN STUDS (LESS THAN 1/4" FROM EDGE OF STUD) 3) ELECTRIC NOT TO PLAN, SUB-PANEL ADDITIONAL OUTLETS, ETC..4) WRAP ALL DUCT WORK WITH INSULATION 5) ELECTRIC TO TERMINATE IN BOXES 6) GROUND ALL METAL ELECTRIC BOXES 7) USE ONLY U.L. APPROVED BOXES CEILING FANS 8) VERIFY POSITIVE CONNECTIONS LEDGER TO STUDS, TIGHTEN PLATE NUTS 9) FIREBLOCKS FURRDOWNS SOOFITS HIDDINE AREAS ETC.. 10) STOPPED INSPECTION
06/02/2004 FRAMING Partial Approval IVRS - Inspection :*/ 1) FRAME OK BUT CANNOT APPROVE UNTIL ELECTRICAL AND MECHANICAL ARE COMPLETE AND BREAK THRU TO EXISTING ARE COMPLETE