Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/16/2004 | FRAMING | Approved | IVRS - Inspection :* | |
| 06/14/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) SECURE ROMEX WITHIN 12" BOXES 2) INSTALL BANG PLATE NAIL PROTECTING ELECTRIC HOLES IN STUDS (LESS THAN 1/4" FROM EDGE OF STUD) 3) ELECTRIC NOT TO PLAN, SUB-PANEL ADDITIONAL OUTLETS, ETC..4) WRAP ALL DUCT WORK WITH INSULATION 5) ELECTRIC TO TERMINATE IN BOXES 6) GROUND ALL METAL ELECTRIC BOXES 7) USE ONLY U.L. APPROVED BOXES CEILING FANS 8) VERIFY POSITIVE CONNECTIONS LEDGER TO STUDS, TIGHTEN PLATE NUTS 9) FIREBLOCKS FURRDOWNS SOOFITS HIDDINE AREAS ETC.. 10) STOPPED INSPECTION |
|
| 06/02/2004 | FRAMING | Partial Approval | IVRS - Inspection :*/ 1) FRAME OK BUT CANNOT APPROVE UNTIL ELECTRICAL AND MECHANICAL ARE COMPLETE AND BREAK THRU TO EXISTING ARE COMPLETE |