Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/20/2004 | FRAMING | Approved | IVRS - Inspection :* | |
| 09/14/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) MAINTAIN MINIMUM 1" CLEARANCE FLUE PIPE TO COMBUSTIBLE 2) INSTALL FLUE PIPE TO H20 HEATER 3) INSTALL FIRE BLOCKS SOUTH WALL UTILITY CLOSET AT FURR DOWN 4) REFEE DUE |
|
| 09/10/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) INSTALL FIRE BLOCKS DROPPED CEILING FURNACE ROOM MAINTAIN MINIMUM 1" CLEARANCE TYPE B VENT TO COMBUSTIBLES |
|
| 09/02/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 08/31/2004 | FRAMING | Partial Approval | IVRS - Inspection :*/ 1) INSTALL FIRE STOP MECH ROOM CEILING AT 2ND FLOOR 2) PLUMBER REPAIRING LEAK AND H20 TESTING 3) RECALL 01035 AND 03035 | |
| 08/30/2004 | FRAMING | Not ready for Inspection | IVRS - Inspection :*/ 1) NOT READY, CANCEL | |
| 08/25/2004 | FRAMING | Not ready for Inspection | IVRS - Inspection :* |