Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/18/2004 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 11/16/2004 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 11/09/2004 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :*/ 1) EPOXY BOLT SPECIAL INSPECTION EAST LIVING ROOM MISSED P. A . 2) CAN'T MIX ABS/PVC 3) TUB VENT RUN AT 45 DEGREE ANGLE OR 6" ABOVE FLOOD RIM BEFORE GOING HORIZONTAL. TUB NOT INSTALLED 4) ALL SW2 SHEAR WALLS TO HAVE A.B. AT 24" ON CENTER 5) MISSED SW2 SHEAR WALL AT LAUNDRY, NEEDS A TRANSFER TO ROOF DECK STUD CUT FOR DRYER DUCT 6) FILL TUBS WITH H20 7) HT22 AT LAUNDRY SW2 SHEAR |