Permit: T04CM00469

Parcel: 141016230

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T04CM00469

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
11/18/2004 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
11/16/2004 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
11/09/2004 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*/ 1) EPOXY BOLT SPECIAL INSPECTION EAST LIVING ROOM MISSED P. A .
2) CAN'T MIX ABS/PVC
3) TUB VENT RUN AT 45 DEGREE ANGLE OR 6" ABOVE FLOOD RIM BEFORE GOING HORIZONTAL. TUB NOT INSTALLED
4) ALL SW2 SHEAR WALLS TO HAVE A.B. AT 24" ON CENTER
5) MISSED SW2 SHEAR WALL AT LAUNDRY, NEEDS A TRANSFER TO ROOF DECK STUD CUT FOR DRYER DUCT
6) FILL TUBS WITH H20
7) HT22 AT LAUNDRY SW2 SHEAR