Inspection Status: Approved
Inspection History: BUILDING PRE-SLAB
| Date |
Description |
Inspector |
Results |
Comments |
| 07/08/2004 |
BUILDING PRE-SLAB |
|
Approved |
IVRS - Inspection :*/ 1) ALL REBAR, FTGS, UFER, CABLES OK |
| 07/06/2004 |
BUILDING PRE-SLAB |
|
Not ready for Inspection |
IVRS - Inspection :*/ 1) PA'S TO BE SECURED, SO THAT THEY DO NOT GET FLUSHED AGAINST FROM AND END UP EXPOSED AFGER POUR 2) STEM TO FLOOR BARS SOME ARE TOO CLOSE TO EARTH 3) NEED ALL PLUMBING WRAPPED 4) AT DEPRESSED SHOWERS STEM TO FLOOR BARS AREN'T IN PLACE 5) HORIZONTAL BAR TO BE CENTERED AND SECURED 6) HORIZONTAL BAR AT 2ND BLDG ? FLAT ON GRADE |