Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING PRE-SLAB
Permit Number - T04CM00467
Inspection Description - BUILDING PRE-SLAB
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/08/2004 | BUILDING PRE-SLAB | Approved | IVRS - Inspection :*/ 1) ALL REBAR, FTGS, UFER, CABLES OK | |
07/06/2004 | BUILDING PRE-SLAB | Not ready for Inspection | IVRS - Inspection :*/ 1) PA'S TO BE SECURED, SO THAT THEY DO NOT GET FLUSHED AGAINST FROM AND END UP EXPOSED AFGER POUR 2) STEM TO FLOOR BARS SOME ARE TOO CLOSE TO EARTH 3) NEED ALL PLUMBING WRAPPED 4) AT DEPRESSED SHOWERS STEM TO FLOOR BARS AREN'T IN PLACE 5) HORIZONTAL BAR TO BE CENTERED AND SECURED 6) HORIZONTAL BAR AT 2ND BLDG ? FLAT ON GRADE |