Permit: T04CM00399

Parcel: 125110430


Addresses:

3832 E SPEEDWAY BL


Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T04CM00399

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
01/03/2005 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*1) PVC DWV ON NORTHSIDE OK. 2) CONTRACTOR TO "REDLINE" PLNA FOR AS BUILT. 3) SEWER NOT INSTALLED PER PLAN. REDLINES ON SITE. OK TO COVER SUBJECT TO REVISED PLAN. 4) M.H. IN RIGHT OF WAY INSPECTED BY PIMA COUNTY
12/30/2004 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*NOT READY - NOT INSTALLED PER PLAN. NO REDLINES ON SITE. 8 1/2" C 11" PROPOSED CHANGE NOT THE WAY IT IS INSTALLED.
12/29/2004 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*/1)PLUMBING ON SOUTH SIDE AT ROOMS 105, 106, & 107 INCLUDING FLOOR SINKS OK TO COVER
12/28/2004 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*/1)AT UPPER FLOOR DRAIN - HORIZONTAL VENTING BELOW FLOOD LEVEL RESTRICTED TO STRUCTURAL CONDITION 2)CHECK PLUMBING SCHEDULE 2 DFYS? FOR MOP SINK AND FLOOR DRAINS LIMITS TRAP SIZE TO 2". PLAN NOT CLEAR ON SIZES, INCORRECT ON DRAWING. 3)OK TO COVER OTHER AREAS. WATER TEST ONE RISER. RETEST AFTER CHANGE.