Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T04CM00346
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/14/2004 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection 0000*/ OK TO COVER ALL AREAS. | |
04/13/2004 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection 0000*/ 1) N/H DWV (ALL AIR ADMITTANCE VALVES) UNDERGROUND OK. OK TO COVER 2) STRAP COPPER IN WALLS ARE REQUIRED 3) YOU MAY NOT HANG PIPE OFF OF OTHER PIPES 4) INDIRECT WASTE PIPING OVER 15' TO BE VENTED SEPERATELY TO THE OUTSIDE. CHANGES OF DIRECTION REQUIRES CELANOUTS |